Dino Lite Microscope Manual

The Dino Lite Microscope is a high-precision digital microscope featuring USB connectivity, adjustable magnification, built-in LED illumination, cross-platform software compatibility, image capture and measurement capabilities, ergonomic design, and various models for industrial, educational, and research applications. Below are key sections for operation, features, software installation, troubleshooting, and specifications.

1. Features at a Glance 2. Installation & Setup 3. Software Installation 4. Specifications 5. Controls and Operation 6. Connecting to Devices 7. Image Capture & Measurement 8. Advanced Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital microscope body, USB cable, LED illumination ring, focus adjustment wheel, measurement calibration software.

FeatureDescription
Magnification Range10x to 200x adjustable magnification
LED IlluminationAdjustable brightness with 8 LED lights
ResolutionUp to 5.0 megapixels depending on model
USB ConnectivityPlug-and-play USB 2.0/3.0 compatibility
Software CompatibilityWindows, Mac OS, Linux support
Measurement ToolsOn-screen calibration and measurement
Image CaptureStill images and video recording
Focus WheelPrecise manual focus adjustment
Stand MountOptional stand for hands-free operation
Portable DesignCompact and lightweight for field use

Installation & Setup

Unpack and inspect all components. Ensure proper surface for operation.

  1. Connect USB cable: Plug USB cable into computer and microscope.
  2. Install software: Download and install Dino Capture software from official website.
  3. Adjust focus: Use focus wheel to achieve clear image.
  4. Set illumination: Adjust LED brightness using control wheel.
  5. Calibrate measurement: Use calibration slide for accurate measurements.

WARNING! Handle with care; avoid dropping or exposing to liquids. Keep lens clean.

Software Installation

Install Dino Capture software for full functionality.

  1. Download software: Visit www.dinolite.com/downloads for latest version.
  2. Run installer: Follow on-screen instructions for your operating system.
  3. Connect microscope: Plug in USB cable after software installation.
  4. Launch software: Open Dino Capture to begin using microscope.
  5. Configure settings: Adjust resolution, frame rate, and capture options.

CAUTION! Ensure computer meets minimum system requirements before installation.

Specifications

Controls and Operation

Access functions via software interface and physical controls.

Physical Controls: Focus adjustment wheel, LED brightness control, USB connection port.

Software Controls: Image capture, video recording, measurement tools, calibration, brightness/contrast adjustment, magnification settings, annotation tools, file management.

Basic Operation: Connect USB, launch software, adjust focus, set illumination, capture images/measurements.

Connecting to Devices

USB connection to computers and compatible devices.

  1. Ensure computer is on and running supported OS.
  2. Connect USB cable to available USB port.
  3. Wait for device recognition (may require driver installation).
  4. Launch Dino Capture software.
  5. Select correct microscope model if prompted.

Tip: Use USB 3.0 ports for better performance with high-resolution models.

Image Capture & Measurement

Capture still images and videos with measurement capabilities.

  1. Focus image: Use focus wheel for clear view.
  2. Set illumination: Adjust LED brightness for optimal lighting.
  3. Capture image: Click capture button in software.
  4. Record video: Use video recording function for dynamic observation.
  5. Measure objects: Use calibration tools for accurate measurements.
  6. Annotate images: Add text, arrows, and other annotations.
  7. Save files: Choose format and location for saved files.

WARNING! Always calibrate before measurements for accuracy.

Advanced Features

Extended Measurement Tools: Distance, angle, radius, area calculations. EDOF (Extended Depth of Focus): Multiple image stacking for enhanced depth. Annotation & Reporting: Add notes and generate reports. Custom Calibration: User-defined measurement scales.

Care & Maintenance

Disconnect USB before cleaning. Use lens cleaning cloth only; no harsh chemicals.

CAUTION! Do not touch lens with fingers; use air blower for dust removal. Store in protective case when not in use.

Regulatory Information

FCC Part 15: Class B digital device compliant. CE marked for European market. RoHS compliant for hazardous substances. Copyright © 2025 Dino Lite; trademarks of AnMo Electronics Corporation. For technical support, visit www.dinolite.com or contact [email protected].

Troubleshooting

SymptomPossible CauseCorrective Action
No image displayedUSB connection/softwareCheck USB connection; reinstall software; try different USB port.
Blurry imageFocus/dirty lensAdjust focus wheel; clean lens with proper cloth.
Poor illuminationLED settings/powerAdjust LED brightness; ensure proper USB power.
Software not recognizing deviceDrivers/USB portReinstall drivers; try different computer; check device manager.
Measurement inaccuraciesCalibrationRecalibrate using calibration slide; check magnification setting.

Reset: Disconnect and reconnect USB; restart software.

Service: [email protected]; www.dinolite.com/support

Dino Lite Microscope Manual © - All Rights Reserved 2025