The Diomed Limited 15 Plus Laser is a medical-grade laser system designed for dermatological and aesthetic treatments. It features a 15W power output, multiple wavelength options, integrated cooling system, touchscreen interface, safety interlocks, treatment handpiece, foot pedal control, and comprehensive treatment protocols. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Laser console with touchscreen display, Treatment handpiece, Foot pedal, Cooling system, Safety goggles, Power cable.
| Feature | Description |
|---|---|
| Power Output | 15W maximum power with adjustable settings |
| Wavelength Options | 1064nm, 532nm, and dual wavelength capability |
| Touchscreen Interface | 7-inch color display for parameter adjustment |
| Integrated Cooling | Built-in air cooling system for handpiece |
| Treatment Handpiece | Ergonomic design with fiber optic delivery |
| Foot Pedal Control | Hands-free operation during treatments |
| Safety Interlocks | Multiple safety systems including key switch |
| Treatment Protocols | Pre-programmed settings for common procedures |
| Energy Settings | Adjustable from 1-15W in 0.1W increments |
| Pulse Duration | Variable from 1-1000ms |
Unpack and inspect contents. Place on stable medical cart or table.
WARNING! Laser is Class 4 device; only trained personnel should install and operate. Ensure proper grounding.
Power on system; follow initial setup wizard.
CAUTION! Always wear appropriate laser safety goggles during setup and operation.
Access settings via touchscreen interface. Front Panel: POWER switch, Key lock, Emergency stop, Handpiece port.
Touchscreen: Power adjustment, Wavelength selection, Pulse duration, Spot size, Treatment protocols, Patient data, System settings.
Treatment Parameters: Power (1-15W), Wavelength (1064nm/532nm/Dual), Pulse duration (1-1000ms), Spot size (1-10mm). Safety: Key lock, Emergency stop, Safety interlocks, Goggle detection. System: Calibration, Maintenance logs, User management, Data export.
Handpiece: Front panel port. Foot pedal: Dedicated connector. Safety goggles: Required for all users.
Tip: Regularly inspect cables and connectors for wear or damage.
Supports various dermatological and aesthetic treatments.
WARNING! Only trained medical professionals should perform treatments. Follow all safety protocols.
Key Lock: Prevents unauthorized use. Emergency Stop: Immediate system shutdown. Safety Interlocks: Multiple redundant safety systems. Goggle Detection: Optional safety sensor. Beam Indicator: Visual and audible ready signals.
Power off and unplug before cleaning. Use approved medical-grade disinfectants. Clean handpiece after each use.
CAUTION! Do not immerse handpiece in liquids. Use only approved cleaning solutions.
FDA Cleared: For specific dermatological indications. CE Marked: Complies with European medical device directives. Laser Class: Class 4 laser product. Copyright © 2024 Diomed Limited; all rights reserved. For technical support, visit www.diomedlaser.com or contact +44 (0)1234 567890.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power | Power cable/outlet | Check power connection; verify outlet function; check fuse. |
| No laser output | Safety interlocks/handpiece | Ensure all safety conditions met; check handpiece connection. |
| Overheating | Cooling system/ventilation | Check cooling fans; ensure adequate ventilation; allow cool-down. |
| Error messages | System faults | Note error code; consult service manual; contact technical support. |
| Handpiece not working | Connection/fiber damage | Check connection; inspect fiber for damage; replace if necessary. |
Reset: System menu > Maintenance > System reset if available.
Service: +44 (0)1234 567890; www.diomedlaser.com