Diomed Limited 15 Plus Laser Manual

The Diomed Limited 15 Plus Laser is a medical-grade laser system designed for dermatological and aesthetic treatments. It features a 15W power output, multiple wavelength options, integrated cooling system, touchscreen interface, safety interlocks, treatment handpiece, foot pedal control, and comprehensive treatment protocols. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Accessories 7. Treatment Procedures 8. Safety Features 9. Maintenance & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Laser console with touchscreen display, Treatment handpiece, Foot pedal, Cooling system, Safety goggles, Power cable.

FeatureDescription
Power Output15W maximum power with adjustable settings
Wavelength Options1064nm, 532nm, and dual wavelength capability
Touchscreen Interface7-inch color display for parameter adjustment
Integrated CoolingBuilt-in air cooling system for handpiece
Treatment HandpieceErgonomic design with fiber optic delivery
Foot Pedal ControlHands-free operation during treatments
Safety InterlocksMultiple safety systems including key switch
Treatment ProtocolsPre-programmed settings for common procedures
Energy SettingsAdjustable from 1-15W in 0.1W increments
Pulse DurationVariable from 1-1000ms

Installation

Unpack and inspect contents. Place on stable medical cart or table.

  1. Position unit: Place on level surface with adequate ventilation.
  2. Connect power: Use provided power cable to appropriate outlet.
  3. Attach handpiece: Connect treatment handpiece to front panel port.
  4. Connect foot pedal: Plug into dedicated foot pedal port.
  5. Install cooling system: Ensure cooling vents are unobstructed.

WARNING! Laser is Class 4 device; only trained personnel should install and operate. Ensure proper grounding.

First-Time Setup

Power on system; follow initial setup wizard.

  1. System initialization: Turn key switch to ON position.
  2. Calibration: Perform handpiece calibration as prompted.
  3. User settings: Set date, time, and user preferences.
  4. Safety check: Verify all safety interlocks are functional.
  5. Test firing: Perform test procedure in safe mode.

CAUTION! Always wear appropriate laser safety goggles during setup and operation.

Specifications

Controls and Settings

Access settings via touchscreen interface. Front Panel: POWER switch, Key lock, Emergency stop, Handpiece port.

Touchscreen: Power adjustment, Wavelength selection, Pulse duration, Spot size, Treatment protocols, Patient data, System settings.

Treatment Parameters: Power (1-15W), Wavelength (1064nm/532nm/Dual), Pulse duration (1-1000ms), Spot size (1-10mm). Safety: Key lock, Emergency stop, Safety interlocks, Goggle detection. System: Calibration, Maintenance logs, User management, Data export.

Connecting Accessories

Handpiece: Front panel port. Foot pedal: Dedicated connector. Safety goggles: Required for all users.

  1. Ensure system is powered off before connecting accessories.
  2. Connect handpiece to labeled port; secure locking mechanism.
  3. Attach foot pedal to designated input.
  4. Verify all connections are secure before powering on.

Tip: Regularly inspect cables and connectors for wear or damage.

Treatment Procedures

Supports various dermatological and aesthetic treatments.

  1. Patient preparation: Clean treatment area and apply coupling gel if required.
  2. Parameter selection: Choose appropriate protocol or custom settings.
  3. Safety check: Ensure goggles are worn by all present.
  4. Treatment delivery: Use foot pedal to activate laser.
  5. Post-treatment: Provide appropriate aftercare instructions.
  6. Documentation: Record treatment parameters in patient file.

WARNING! Only trained medical professionals should perform treatments. Follow all safety protocols.

Safety Features

Key Lock: Prevents unauthorized use. Emergency Stop: Immediate system shutdown. Safety Interlocks: Multiple redundant safety systems. Goggle Detection: Optional safety sensor. Beam Indicator: Visual and audible ready signals.

Maintenance & Cleaning

Power off and unplug before cleaning. Use approved medical-grade disinfectants. Clean handpiece after each use.

CAUTION! Do not immerse handpiece in liquids. Use only approved cleaning solutions.

Regulatory Information

FDA Cleared: For specific dermatological indications. CE Marked: Complies with European medical device directives. Laser Class: Class 4 laser product. Copyright © 2024 Diomed Limited; all rights reserved. For technical support, visit www.diomedlaser.com or contact +44 (0)1234 567890.

Troubleshooting

SymptomPossible CauseCorrective Action
No powerPower cable/outletCheck power connection; verify outlet function; check fuse.
No laser outputSafety interlocks/handpieceEnsure all safety conditions met; check handpiece connection.
OverheatingCooling system/ventilationCheck cooling fans; ensure adequate ventilation; allow cool-down.
Error messagesSystem faultsNote error code; consult service manual; contact technical support.
Handpiece not workingConnection/fiber damageCheck connection; inspect fiber for damage; replace if necessary.

Reset: System menu > Maintenance > System reset if available.