The Diomed Limited 15 Plus Laser is a medical-grade laser system designed for various therapeutic applications. This service manual provides comprehensive information for qualified technicians including safety protocols, technical specifications, maintenance procedures, troubleshooting guides, and regulatory compliance information. Below are key sections covering all aspects of service and maintenance.
Critical safety protocols for operating and servicing the Diomed 15 Plus Laser system.
| Safety Feature | Description |
|---|---|
| Laser Safety Interlocks | Prevents laser operation when access panels are open |
| Emergency Stop | Immediate system shutdown in case of emergency |
| Eye Protection | Class 4 laser requires appropriate protective eyewear |
| Cooling System | Maintains optimal operating temperature |
| Power Supply Safety | Isolated high-voltage components |
Detailed description of system components and their functions.
WARNING! Only qualified service personnel should access internal components.
Step-by-step installation guide for qualified technicians.
CAUTION! Ensure proper grounding and electrical safety measures.
Proper operating procedures and user interface navigation.
Control Panel: Power On/Off, Mode Selection, Power Adjustment, Timer Settings.
Display Indicators: Power Level, Operation Mode, System Status, Error Codes.
Operation Modes: Continuous wave for constant output, Pulsed mode for intermittent delivery. Power Settings: Adjustable from 1W to 15W in 0.1W increments. Safety Features: Automatic shutdown on fault detection, temperature monitoring, interlock verification.
Routine maintenance procedures and recommended intervals.
| Maintenance Task | Frequency | Procedure |
|---|---|---|
| External Cleaning | Daily | Wipe exterior with approved disinfectant |
| Air Filter Inspection | Monthly | Check and clean/replace air filters |
| Laser Output Verification | Quarterly | Measure and verify laser power output |
| Full System Calibration | Annually | Complete system calibration and certification |
| Safety Interlock Testing | Semi-annually | Verify all safety systems are operational |
Detailed calibration steps for maintaining optimal performance.
Note: Use only factory-approved calibration equipment.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No laser output | Safety interlock fault | Check all access panels are properly closed |
| Overheating warning | Blocked air vents | Clean air filters and ensure adequate ventilation |
| Error code E-01 | Power supply fault | Check power connections and reset system |
| Inconsistent power | Fiber optic damage | Inspect and replace delivery fiber if necessary |
| Display not responding | Control board issue | Reset system and check control board connections |
Authorized replacement parts and installation procedures.
WARNING! Use only genuine Diomed replacement parts.
Compliance with international standards and regulations.
FDA Class II Medical Device, CE Marked, IEC 60601-1 Safety Standard, IEC 60825-1 Laser Safety, RoHS Compliant. Manufactured under ISO 13485 Quality System. Copyright © Diomed Limited. All rights reserved. For technical support and service inquiries, contact authorized service centers only.
Diomed Limited Technical Support and Service Centers
Note: Always quote serial number when requesting service support.