Diomed Limited 15 Plus Laser Service Manual

The Diomed Limited 15 Plus Laser is a medical-grade laser system designed for various therapeutic applications. This service manual provides comprehensive information for qualified technicians including safety protocols, technical specifications, maintenance procedures, troubleshooting guides, and regulatory compliance information. Below are key sections covering all aspects of service and maintenance.

1. Safety Information 2. Technical Specifications 3. System Overview 4. Installation Procedures 5. Operation Guidelines 6. Maintenance Schedule 7. Calibration Procedures 8. Troubleshooting Guide 9. Parts Replacement 10. Regulatory Compliance 11. Contact Information

Safety Information

Critical safety protocols for operating and servicing the Diomed 15 Plus Laser system.

Safety FeatureDescription
Laser Safety InterlocksPrevents laser operation when access panels are open
Emergency StopImmediate system shutdown in case of emergency
Eye ProtectionClass 4 laser requires appropriate protective eyewear
Cooling SystemMaintains optimal operating temperature
Power Supply SafetyIsolated high-voltage components

Technical Specifications

System Overview

Detailed description of system components and their functions.

  1. Laser Head Assembly: Contains laser diodes and output optics
  2. Power Supply Unit: Regulates and supplies power to laser components
  3. Control Panel: User interface for system operation and settings
  4. Cooling System: Maintains optimal operating temperature
  5. Safety Interlocks: Multiple safety mechanisms for operator protection

WARNING! Only qualified service personnel should access internal components.

Installation Procedures

Step-by-step installation guide for qualified technicians.

  1. Unpack and inspect all components for damage during shipping
  2. Position unit on stable, level surface with adequate ventilation
  3. Connect to appropriate power source (100-240V AC)
  4. Install laser delivery fiber according to manufacturer specifications
  5. Perform initial system calibration and safety checks
  6. Verify all safety interlocks are functioning properly

CAUTION! Ensure proper grounding and electrical safety measures.

Operation Guidelines

Proper operating procedures and user interface navigation.

Control Panel: Power On/Off, Mode Selection, Power Adjustment, Timer Settings.

Display Indicators: Power Level, Operation Mode, System Status, Error Codes.

Operation Modes: Continuous wave for constant output, Pulsed mode for intermittent delivery. Power Settings: Adjustable from 1W to 15W in 0.1W increments. Safety Features: Automatic shutdown on fault detection, temperature monitoring, interlock verification.

Maintenance Schedule

Routine maintenance procedures and recommended intervals.

Maintenance TaskFrequencyProcedure
External CleaningDailyWipe exterior with approved disinfectant
Air Filter InspectionMonthlyCheck and clean/replace air filters
Laser Output VerificationQuarterlyMeasure and verify laser power output
Full System CalibrationAnnuallyComplete system calibration and certification
Safety Interlock TestingSemi-annuallyVerify all safety systems are operational

Calibration Procedures

Detailed calibration steps for maintaining optimal performance.

  1. Connect calibrated power meter to laser output
  2. Allow system to warm up for 15 minutes
  3. Verify power output at multiple settings (5W, 10W, 15W)
  4. Adjust calibration parameters if deviation exceeds ±5%
  5. Document calibration results in service log
  6. Apply calibration sticker with date and technician ID

Note: Use only factory-approved calibration equipment.

Troubleshooting Guide

SymptomPossible CauseCorrective Action
No laser outputSafety interlock faultCheck all access panels are properly closed
Overheating warningBlocked air ventsClean air filters and ensure adequate ventilation
Error code E-01Power supply faultCheck power connections and reset system
Inconsistent powerFiber optic damageInspect and replace delivery fiber if necessary
Display not respondingControl board issueReset system and check control board connections

Parts Replacement

Authorized replacement parts and installation procedures.

WARNING! Use only genuine Diomed replacement parts.

Regulatory Compliance

Compliance with international standards and regulations.

FDA Class II Medical Device, CE Marked, IEC 60601-1 Safety Standard, IEC 60825-1 Laser Safety, RoHS Compliant. Manufactured under ISO 13485 Quality System. Copyright © Diomed Limited. All rights reserved. For technical support and service inquiries, contact authorized service centers only.

Contact Information

Diomed Limited Technical Support and Service Centers

Note: Always quote serial number when requesting service support.

Diomed Limited 15 Plus Laser Service Manual © - All Rights Reserved 2025