Dionex Chromeleon is a comprehensive chromatography data system software for instrument control, data acquisition, processing, and reporting. The software supports various chromatography techniques including HPLC, UHPLC, IC, and GC systems. Below are key sections covering software overview, installation, configuration, operation, data analysis, and troubleshooting.
Chromeleon CDS provides complete workflow solutions for chromatography laboratories with intuitive interface and powerful data management capabilities.
| Feature | Description |
|---|---|
| Instrument Control | Supports multiple chromatography instruments simultaneously |
| Data Acquisition | Real-time data collection and monitoring |
| Method Development | Visual method editor with drag-and-drop functionality |
| Data Processing | Advanced peak integration and quantification |
| Reporting | Customizable report templates and automated reporting |
| Compliance | 21 CFR Part 11 compliant with audit trail |
| Multi-user | Role-based access control and user management |
| Database | Centralized data storage and management |
| Workflow Automation | Sequence-based automated analysis |
| Data Security | Encrypted data storage and backup |
Minimum hardware and software requirements for Chromeleon installation.
Step-by-step installation procedure for Chromeleon software.
IMPORTANT! Ensure all prerequisites are met before installation. Close all other applications during installation.
Configure and connect chromatography instruments to Chromeleon system.
Note: Ensure instruments are powered on and connected before configuration.
Create and optimize chromatography methods using Chromeleon method editor.
Run sequences and acquire chromatographic data.
Tip: Use sequence templates for routine analysis to save time.
Process chromatographic data and perform quantitative analysis.
| Processing Step | Description |
|---|---|
| Peak Integration | Automatic and manual peak detection and integration |
| Baseline Correction | Adjust baseline for accurate peak quantification |
| Calibration | Create calibration curves using standards |
| Quantification | Calculate sample concentrations based on calibration |
| System Suitability | Evaluate system performance parameters |
| Data Review | Review and approve processed data |
Generate comprehensive reports and export data.
Manage user accounts and access permissions.
Regular maintenance tasks and software updates.
CAUTION! Always backup data before performing software updates.
| Issue | Possible Cause | Solution |
|---|---|---|
| Instrument not detected | Connection issues/drivers | Check cables; reinstall drivers; verify communication settings |
| Software crashes | Memory issues/corruption | Restart software; check system resources; reinstall if persistent |
| Data acquisition failure | Method errors/instrument | Verify method parameters; check instrument status; restart acquisition |
| Database connection lost | Network/SQL issues | Check network connectivity; restart SQL service; verify credentials |
| Performance slow | Resource constraints | Close other applications; increase RAM; optimize database |
Support: Contact Thermo Fisher Scientific support at 1-800-532-4752 or visit www.thermofisher.com/chromeleon