Dionex Chromeleon Software Manual

Dionex Chromeleon is a comprehensive chromatography data system software for instrument control, data acquisition, processing, and reporting. The software supports various chromatography techniques including HPLC, UHPLC, IC, and GC systems. Below are key sections covering software overview, installation, configuration, operation, data analysis, and troubleshooting.

1. Software Overview 2. System Requirements 3. Installation Guide 4. Instrument Configuration 5. Method Development 6. Data Acquisition 7. Data Processing & Analysis 8. Reporting Features 9. User Management 10. Maintenance & Updates 11. Troubleshooting

Software Overview

Chromeleon CDS provides complete workflow solutions for chromatography laboratories with intuitive interface and powerful data management capabilities.

FeatureDescription
Instrument ControlSupports multiple chromatography instruments simultaneously
Data AcquisitionReal-time data collection and monitoring
Method DevelopmentVisual method editor with drag-and-drop functionality
Data ProcessingAdvanced peak integration and quantification
ReportingCustomizable report templates and automated reporting
Compliance21 CFR Part 11 compliant with audit trail
Multi-userRole-based access control and user management
DatabaseCentralized data storage and management
Workflow AutomationSequence-based automated analysis
Data SecurityEncrypted data storage and backup

System Requirements

Minimum hardware and software requirements for Chromeleon installation.

Installation Guide

Step-by-step installation procedure for Chromeleon software.

  1. Run setup.exe as administrator from installation media
  2. Accept license agreement and choose installation type
  3. Select installation directory and components
  4. Configure database connection settings
  5. Set up system administrator account
  6. Complete installation and restart system
  7. Run post-installation configuration wizard

IMPORTANT! Ensure all prerequisites are met before installation. Close all other applications during installation.

Instrument Configuration

Configure and connect chromatography instruments to Chromeleon system.

  1. Open Instrument Configuration workspace
  2. Add new instrument using device discovery
  3. Configure communication parameters (COM port, IP address)
  4. Set up instrument properties and capabilities
  5. Test instrument connection and communication
  6. Save instrument configuration

Note: Ensure instruments are powered on and connected before configuration.

Method Development

Create and optimize chromatography methods using Chromeleon method editor.

  1. Open Method Editor from main menu
  2. Select instrument and create new method
  3. Define chromatographic parameters (flow rate, gradient, temperature)
  4. Configure detector settings (wavelength, sampling rate)
  5. Set up data acquisition parameters
  6. Validate method performance
  7. Save method to method library

Data Acquisition

Run sequences and acquire chromatographic data.

  1. Create new sequence with sample information
  2. Assign methods and processing methods to sequence
  3. Set sequence parameters (injection volume, run time)
  4. Start sequence and monitor real-time data
  5. Review acquired chromatograms
  6. Export data for further analysis

Tip: Use sequence templates for routine analysis to save time.

Data Processing & Analysis

Process chromatographic data and perform quantitative analysis.

Processing StepDescription
Peak IntegrationAutomatic and manual peak detection and integration
Baseline CorrectionAdjust baseline for accurate peak quantification
CalibrationCreate calibration curves using standards
QuantificationCalculate sample concentrations based on calibration
System SuitabilityEvaluate system performance parameters
Data ReviewReview and approve processed data

Reporting Features

Generate comprehensive reports and export data.

  1. Select report template from library
  2. Choose data to include in report
  3. Customize report layout and formatting
  4. Add headers, footers, and company logo
  5. Preview report before generation
  6. Export to PDF, Excel, or print directly

User Management

Manage user accounts and access permissions.

Maintenance & Updates

Regular maintenance tasks and software updates.

  1. Perform regular database backups
  2. Update software with latest patches
  3. Archive old data to free storage space
  4. Verify system performance regularly
  5. Update instrument drivers as needed

CAUTION! Always backup data before performing software updates.

Troubleshooting

IssuePossible CauseSolution
Instrument not detectedConnection issues/driversCheck cables; reinstall drivers; verify communication settings
Software crashesMemory issues/corruptionRestart software; check system resources; reinstall if persistent
Data acquisition failureMethod errors/instrumentVerify method parameters; check instrument status; restart acquisition
Database connection lostNetwork/SQL issuesCheck network connectivity; restart SQL service; verify credentials
Performance slowResource constraintsClose other applications; increase RAM; optimize database

Support: Contact Thermo Fisher Scientific support at 1-800-532-4752 or visit www.thermofisher.com/chromeleon