The Dionex IC 5000 is a high-performance ion chromatography system designed for analytical laboratories, featuring advanced conductivity detection, automated eluent generation, temperature-controlled compartments, Chromeleon chromatography data system compatibility, and comprehensive automation capabilities. Below are key sections for system overview, installation, operation, maintenance, and troubleshooting.
Key components: High-pressure pump, conductivity detector, automated eluent generator, temperature-controlled column compartment, autosampler, and Chromeleon software interface.
| Component | Description |
|---|---|
| High-pressure pump | Dual-piston design for pulse-free eluent delivery |
| Conductivity detector | Temperature-controlled with auto-suppression |
| Eluent generator | Automated eluent preparation with cartridge-based technology |
| Column compartment | Temperature control from 5°C to 80°C |
| Autosampler | 96-vial capacity with temperature control option |
| Chromeleon software | Comprehensive chromatography data system |
| Power switch | Main system power control |
| Emergency stop | Immediate system shutdown for safety |
| Status indicators | LED displays for system status and alerts |
| Communication ports | Ethernet and USB connectivity |
Unpack and verify all components. Ensure proper laboratory environment.
WARNING! System contains high-pressure components; install in authorized laboratory only. Ensure proper grounding.
Power on system; follow Chromeleon software setup wizard.
CAUTION! Wear appropriate personal protective equipment when handling chemicals and solvents.
Access system controls via touchscreen interface or Chromeleon software. Front Panel: POWER, EMERGENCY STOP, STATUS, MENU.
Software Interface: Method editor, sequence table, real-time monitoring, data processing, report generation.
Pump Control: Flow rate, pressure limits, composition gradient. Detector Settings: Cell temperature, auto-zero, output range. Column Oven: Temperature setpoint, equilibration time. Autosampler: Injection volume, wash cycles, tray temperature. System: Pressure monitoring, leak detection, maintenance counters.
Create and optimize separation methods for various analytes.
Tip: Use method scouting with Chromeleon software for rapid method development.
Chromeleon software provides comprehensive data processing capabilities.
WARNING! Maintain proper data backup procedures. Validate all calculation methods.
Regular maintenance ensures optimal system performance and data quality.
| Component | Maintenance Interval | Procedure |
|---|---|---|
| Pump seals | Every 6 months or 2000 hours | Replace pump seals; flush with water |
| Detector cell | Monthly or as needed | Clean with 0.1M HNO3; rinse with water |
| Eluent cartridges | When depleted | Replace cartridge; prime system |
| Injection valve | Every 3 months | Clean rotor seal; replace if worn |
| Filters | Monthly | Replace inlet and outlet filters |
| Tubing | As needed | Check for leaks; replace if damaged |
CAUTION! Always depressurize system before performing maintenance. Use appropriate solvents and safety equipment.
Dionex IC 5000 complies with FDA 21 CFR Part 11 for electronic records and signatures, ISO 9001 quality management system, CE marking for European market, and RoHS compliance for hazardous substances. Copyright © Thermo Fisher Scientific. For technical support, visit www.thermofisher.com or contact 1-800-532-4752.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| High pressure | Clogged column/filter | Replace guard column; backflush column; replace filters |
| Low pressure | Leak or air in system | Check fittings; prime pump; purge detectors |
| Noisy baseline | Contaminated eluent or cell | Prepare fresh eluent; clean detector cell |
| Peak tailing | Column degradation or contamination | Regenerate or replace column; check sample matrix |
| Retention time shift | Temperature or flow variation | Verify column temperature; check pump calibration |
| No injection | Autosampler error | Check syringe; verify needle position; clean injector |
| Communication error | Network or cable issue | Check Ethernet connection; restart software |
Reset: System > Maintenance > System Reset if available.
Service: 1-800-532-4752; www.thermofisher.com