Dionex ICS-1600 Manual

The Dionex ICS-1600 is a high-performance ion chromatography system designed for analytical laboratories, featuring advanced conductivity detection, automated eluent generation, and Chromeleon chromatography data system compatibility. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Procedures 8. Maintenance Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: High-pressure pump, conductivity detector, automated eluent generator, injection valve, column oven, and Chromeleon software interface.

FeatureDescription
High-pressure pumpCapable of flow rates from 0.001 to 5.0 mL/min
Conductivity detectorTemperature-controlled with electronic suppression
Automated eluent generatorGenerates high-purity eluents on-demand
Injection valveSupports manual and automated injections
Column ovenTemperature range 5°C to 80°C
Chromeleon softwareComplete system control and data analysis
Power input100-240V AC, 50/60Hz
CommunicationEthernet and USB connectivity
Dimensions55 cm W × 45 cm D × 45 cm H
WeightApproximately 25 kg

Installation

Unpack and inspect contents. Place on stable laboratory bench.

  1. Position system: Ensure adequate clearance for ventilation and access.
  2. Connect solvent lines: Install eluent reservoirs and connect tubing.
  3. Connect waste: Route waste tubing to appropriate container.
  4. Power connection: Plug into grounded electrical outlet.
  5. Computer connection: Connect via Ethernet or USB to control computer.

WARNING! System contains high-pressure components; ensure all connections are secure before operation.

First-Time Setup

Power on system; initialize Chromeleon software.

  1. System priming: Purge pump and lines to remove air bubbles.
  2. Column installation: Install and condition analytical column.
  3. Detector calibration: Perform baseline calibration and noise test.
  4. Method development: Create or load analytical methods.
  5. System verification: Run quality control standards.

CAUTION! Use only HPLC-grade solvents and ultrapure water.

Specifications

Controls and Settings

Access system controls via Chromeleon software interface. Front Panel: POWER, STATUS indicators, emergency stop.

Software Controls: Method editor, sequence table, real-time monitoring, data processing, report generation.

Pump: Flow rate, pressure limits, composition. Detector: Range, temperature, output filter, auto-zero. Oven: Temperature, equilibration time. Injector: Injection volume, wash cycles. Eluent Generator: Concentration, refill cycles.

Connecting Devices

Solvent delivery: Eluent reservoirs, degasser. Detection: Conductivity cell, suppressor. Data: Computer interface.

  1. Turn off system before connecting components.
  2. Connect solvent lines using appropriate fittings.
  3. Install column with correct orientation.
  4. Connect detector cell and suppressor.
  5. Establish computer communication.

Tip: Use only Dionex-approved tubing and fittings for optimal performance.

Operating Procedures

Supports isocratic and gradient elution methods.

  1. System preparation: Prime pump, equilibrate column.
  2. Sample injection: Load sample via manual injector or autosampler.
  3. Method execution: Start chromatographic run.
  4. Data acquisition: Monitor real-time chromatogram.
  5. Peak integration: Process data using Chromeleon.
  6. System shutdown: Flush with appropriate storage solvent.
  7. Calibration: Run calibration standards for quantification.
  8. Quality control: Monitor system suitability parameters.

WARNING! Always depressurize system before opening fluidic connections.

Maintenance Features

Automated diagnostics: System self-check on startup. Maintenance reminders: Scheduled component replacement alerts. Data backup: Automated method and data archiving.

Care & Cleaning

Power off before cleaning. Wipe exterior with mild detergent; clean fluidic paths with appropriate solvents.

CAUTION! Use only compatible solvents; avoid abrasive cleaners.

Regulatory Information

CE marked: Complies with European Union safety standards. FDA: Meets requirements for pharmaceutical applications. Copyright © 2025 Thermo Fisher Scientific; trademarks of Thermo Fisher Scientific. For technical support, visit www.thermofisher.com or contact 1-800-532-4752.

Troubleshooting

SymptomPossible CauseCorrective Action
High pressureColumn blockageCheck and replace column; flush system.
Noisy baselineAir bubbles/contaminationDegas solvents; purge system; clean cell.
Peak tailingColumn degradationReplace column; check mobile phase pH.
No flowPump seal failureReplace pump seals; check for leaks.
Communication errorCable/software issueCheck connections; restart software.

Reset: Software > System > Reset configuration.

Service: 1-800-532-4752; www.thermofisher.com