The Dionex ICS-1600 is a high-performance ion chromatography system designed for analytical laboratories, featuring advanced conductivity detection, automated eluent generation, and Chromeleon chromatography data system compatibility. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: High-pressure pump, conductivity detector, automated eluent generator, injection valve, column oven, and Chromeleon software interface.
| Feature | Description |
|---|---|
| High-pressure pump | Capable of flow rates from 0.001 to 5.0 mL/min |
| Conductivity detector | Temperature-controlled with electronic suppression |
| Automated eluent generator | Generates high-purity eluents on-demand |
| Injection valve | Supports manual and automated injections |
| Column oven | Temperature range 5°C to 80°C |
| Chromeleon software | Complete system control and data analysis |
| Power input | 100-240V AC, 50/60Hz |
| Communication | Ethernet and USB connectivity |
| Dimensions | 55 cm W × 45 cm D × 45 cm H |
| Weight | Approximately 25 kg |
Unpack and inspect contents. Place on stable laboratory bench.
WARNING! System contains high-pressure components; ensure all connections are secure before operation.
Power on system; initialize Chromeleon software.
CAUTION! Use only HPLC-grade solvents and ultrapure water.
Access system controls via Chromeleon software interface. Front Panel: POWER, STATUS indicators, emergency stop.
Software Controls: Method editor, sequence table, real-time monitoring, data processing, report generation.
Pump: Flow rate, pressure limits, composition. Detector: Range, temperature, output filter, auto-zero. Oven: Temperature, equilibration time. Injector: Injection volume, wash cycles. Eluent Generator: Concentration, refill cycles.
Solvent delivery: Eluent reservoirs, degasser. Detection: Conductivity cell, suppressor. Data: Computer interface.
Tip: Use only Dionex-approved tubing and fittings for optimal performance.
Supports isocratic and gradient elution methods.
WARNING! Always depressurize system before opening fluidic connections.
Automated diagnostics: System self-check on startup. Maintenance reminders: Scheduled component replacement alerts. Data backup: Automated method and data archiving.
Power off before cleaning. Wipe exterior with mild detergent; clean fluidic paths with appropriate solvents.
CAUTION! Use only compatible solvents; avoid abrasive cleaners.
CE marked: Complies with European Union safety standards. FDA: Meets requirements for pharmaceutical applications. Copyright © 2025 Thermo Fisher Scientific; trademarks of Thermo Fisher Scientific. For technical support, visit www.thermofisher.com or contact 1-800-532-4752.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| High pressure | Column blockage | Check and replace column; flush system. |
| Noisy baseline | Air bubbles/contamination | Degas solvents; purge system; clean cell. |
| Peak tailing | Column degradation | Replace column; check mobile phase pH. |
| No flow | Pump seal failure | Replace pump seals; check for leaks. |
| Communication error | Cable/software issue | Check connections; restart software. |
Reset: Software > System > Reset configuration.
Service: 1-800-532-4752; www.thermofisher.com