The Dionex Ultimate 3000 is a high-performance ultra-high performance liquid chromatography system designed for analytical laboratories. It features advanced pump technology, precise temperature control, multiple detection options, and intuitive software control. Below are key sections covering system overview, installation, operation, maintenance, and troubleshooting.
Key components: Binary pump, autosampler, column compartment, multiple detectors (DAD, FLD, RID), and Chromeleon software.
| Component | Description |
|---|---|
| Binary Pump | High-pressure mixing with flow rates from 0.001 to 10 mL/min |
| Autosampler | Temperature-controlled with 96-well plate capacity |
| Column Compartment | Temperature range 5-110°C with active preheating |
| DAD Detector | Wavelength range 190-800 nm |
| FLD Detector | Programmable excitation and emission wavelengths |
| RID Detector | Refractive index detection |
| Software | Chromeleon Chromatography Data System |
| Solvent Cabinet | 4-channel degasser with 2L bottle capacity |
| Waste Container | 2L capacity with level sensor |
| Power Supply | 100-240V AC, 50/60Hz |
Unpack and inspect all components. Ensure proper laboratory environment.
WARNING! System contains high-pressure components. Wear appropriate PPE during installation.
The Ultimate 3000 operates on UHPLC principles with sub-2μm particle columns for high resolution and fast separations.
Pump Operation: Dual piston design with active inlet valve and electronic pressure control.
Autosampler: Uses needle-in-loop design for minimal carryover and precise injections.
Detection: Multiple detection options including diode array, fluorescence, and refractive index.
System controlled via Chromeleon Chromatography Data System.
Interface: Touch-screen display and computer software control.
Develop and optimize UHPLC methods for various applications.
Tip: Start with generic gradients and optimize for specific analytes.
Regular maintenance ensures optimal performance and extends system lifetime.
CAUTION! Always depressurize system before performing maintenance.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| High pressure | Column blockage | Replace column; flush system |
| Pressure fluctuations | Air bubbles | Purge system; degas solvents |
| Peak tailing | Column degradation | Replace column; check pH |
| Retention time shift | Temperature variation | Check column thermostat |
| No injection | Autosampler error | Check needle position; clean ports |
| Baseline noise | Detector lamp aging | Replace lamp; check mobile phase |
| Low sensitivity | Flow cell contamination | Clean flow cell; check detector settings |
CE marked; complies with IVDR 2017/746 for in-vitro diagnostics. FDA 21 CFR Part 11 compliant software options available. RoHS and WEEE compliant.
Quality Standards: ISO 9001, ISO 13485 certified manufacturing.
For technical assistance, service, or training:
Emergency Service: Available 24/7 for critical system failures.