Diplomat 5 000 BTU Portable Air Conditioner Manual

The Diplomat 5 000 BTU Portable Air Conditioner is a compact cooling unit designed for small rooms up to 150 square feet. Features include digital controls, 24-hour programmable timer, remote control, 3 fan speeds, auto swing louvers, washable air filter, and dehumidification function. Operates on standard 115V household current with energy-saving sleep mode. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Window Installation Kit 7. Operation Modes 8. Maintenance 9. Energy Saving Tips 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Portable AC unit, Remote Control, Window installation kit, Exhaust hose, Air filter, Power cord.

FeatureDescription
Cooling Capacity5,000 BTU - suitable for rooms up to 150 sq ft
Digital ControlsLED display with temperature and mode indicators
Remote ControlFull function remote for convenient operation
Timer Function24-hour programmable on/off timer
Fan Speeds3 speed settings (Low, Medium, High)
Auto Swing LouversAutomatic vertical air direction control
Washable Air FilterRemovable and reusable air filter
DehumidificationRemoves up to 1.5 pints per hour
Sleep ModeQuiet operation with energy saving settings
Power Requirements115V, 60Hz, 5.5A

Installation

Unpack and inspect all components. Place unit on level surface near window.

  1. Install window kit: Adjust window bracket to fit window opening, secure in place.
  2. Connect exhaust hose: Attach hose to unit and window bracket securely.
  3. Position unit: Place at least 20 inches from walls and furniture for proper airflow.
  4. Plug into dedicated outlet: Use grounded 115V outlet only.

WARNING! Ensure proper ventilation; do not block air intake or exhaust. Keep unit upright during installation.

First-Time Setup

After installation, allow unit to stand upright for 2 hours before operation.

  1. Power on unit: Press POWER button on control panel or remote.
  2. Select mode: Choose COOL, FAN, DEHUMIDIFY, or AUTO mode.
  3. Set temperature: Use +/- buttons to set desired temperature (61°F-88°F).
  4. Adjust fan speed: Select from 3 speed settings as needed.
  5. Program timer: Set 24-hour on/off schedule if desired.

CAUTION! Do not operate without proper exhaust installation. Ensure window kit is securely sealed.

Specifications

Controls and Settings

Control Panel: POWER, MODE, FAN SPEED, TEMP +/- , TIMER, SLEEP, SWING.

Remote: POWER, MODE, FAN, TEMP, TIMER, SLEEP, SWING.

Modes: COOL (temperature control), FAN (circulation only), DEHUMIDIFY (moisture removal), AUTO (automatic temperature adjustment). Fan Speeds: LOW, MEDIUM, HIGH. Timer: 24-hour programmable on/off schedule. Sleep Mode: Auto temperature adjustment for comfort and energy savings. Swing: Automatic vertical air direction.

Window Installation Kit

Includes adjustable window bracket, exhaust hose, hose connectors, and window seals.

  1. Measure window opening and adjust bracket accordingly.
  2. Secure bracket in window opening using provided hardware.
  3. Connect exhaust hose to rear of unit and window bracket.
  4. Seal any gaps with included weather stripping.

Tip: For maximum efficiency, minimize the length of exhaust hose and ensure tight seals.

Operation Modes

Multiple operating modes for different comfort needs.

  1. Cool Mode: Set desired temperature for automatic cooling operation.
  2. Fan Mode: Air circulation without cooling - 3 speed settings available.
  3. Dehumidify Mode: Removes excess moisture from air automatically.
  4. Auto Mode: Unit automatically selects cooling or fan operation based on room temperature.
  5. Sleep Mode: Gradually adjusts temperature for comfortable sleeping while saving energy.

WARNING! Do not operate in temperatures below 61°F. Allow unit to rest 3 minutes between cycles.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter every 2 weeks: Remove, wash with mild detergent, dry completely.
  2. Clean unit exterior: Use soft, damp cloth only - no harsh chemicals.
  3. Check exhaust hose: Ensure no obstructions or damage.
  4. End of season: Drain any remaining water, clean thoroughly, and store upright.

CAUTION! Always unplug unit before cleaning. Do not use water to clean interior components.

Energy Saving Tips

Close windows and doors when operating. Use timer to pre-cool room. Clean filter regularly. Set temperature no lower than 72°F. Use sleep mode overnight. Ensure proper installation with no air leaks.

Regulatory Information

UL Listed for safety. EPA compliant. Energy Star certified. Manufactured to meet industry standards. Copyright © 2024 Diplomat Appliances. For support, visit www.diplomatappliances.com or contact 1-800-555-1234.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not coolingDirty filter/improper installationClean air filter; check exhaust hose connection; ensure proper window seal.
Water leakageFull condensate tankCheck and empty water collection tank; ensure unit is level.
Loud noiseObstructions/vibrationCheck for objects near fan; ensure unit is on level surface.
Remote not workingBatteries/obstaclesReplace batteries; ensure clear line of sight to unit.
Unit not turning onPower source/timerCheck power outlet; ensure timer is not activated; check circuit breaker.

Reset: Unplug unit for 5 minutes, then restart.

Service: 1-800-555-1234; www.diplomatappliances.com