The Dipstick 2272 is a precision measurement instrument designed for accurate fluid level monitoring in industrial applications. This operator's manual provides comprehensive guidance on proper usage, maintenance, and safety procedures for optimal performance. Below are key sections covering features, operation, maintenance, troubleshooting, and technical specifications.
Key components: Precision measurement probe, digital display unit, calibration controls, data output port, protective carrying case.
| Feature | Description |
|---|---|
| Measurement probe | Stainless steel construction for accurate fluid level detection |
| Digital display | LCD screen showing current measurement readings |
| Calibration controls | For precise instrument calibration |
| Data output port | For connection to data logging systems |
| Battery compartment | Holds standard AA batteries for portable operation |
| Power switch | Turns instrument on/off |
| Zero adjustment | Calibrates baseline measurement |
| Units selector | Switches between metric and imperial units |
| Hold function | Freezes current reading on display |
| Auto power-off | Conserves battery life during inactivity |
Unpack and inspect all components. Ensure proper storage conditions.
WARNING! Handle probe with care to avoid damage to sensitive components. Keep away from extreme temperatures.
Power on instrument; perform initial calibration.
CAUTION! Always calibrate in controlled environment for accurate measurements.
Access functions via front panel controls. Main controls: POWER, ZERO, HOLD, UNITS, CALIBRATE.
Display indicators: Battery level, measurement units, hold status, error codes.
Calibration: Access through CALIBRATE button; follow on-screen prompts. Units selection: Toggle between inches and centimeters. Zero function: Resets baseline measurement. Hold function: Freezes current reading for recording.
Data output: RS-232 port for computer connection. External power: DC input jack.
Tip: Use shielded cables for data transfer in electrically noisy environments.
Standard operating procedure for accurate measurements.
WARNING! Do not force probe into restricted spaces. Avoid contact with corrosive substances.
Over-range protection: Prevents damage from excessive measurements. Low battery indicator: Warns when batteries need replacement. Auto power-off: Conserves battery life. Probe protection: Built-in strain relief.
Power off before cleaning. Use soft cloth with mild detergent for probe cleaning. Store in protective case.
CAUTION! Do not immerse electronic unit in liquids. Avoid abrasive cleaners on display.
FCC Part 15: Class A digital device; complies with industrial equipment standards. CE certified for European markets. Manufactured under ISO 9001 quality standards. Copyright © 2025 Dipstick Instruments; all rights reserved. For technical support, visit www.dipstickinstruments.com or contact 1-800-555-2272.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace batteries; check polarity. |
| Inaccurate readings | Need calibration | Perform zero calibration; check probe condition. |
| Erratic display | Electrical interference | Move away from power sources; check connections. |
| Probe not detected | Loose connection | Check probe connection; inspect cable for damage. |
| Battery drains quickly | Old batteries | Use fresh alkaline batteries; avoid rechargeable. |
Reset: Remove batteries for 30 seconds to reset microprocessor.
Service: 1-800-555-2272; www.dipstickinstruments.com